| Main Features:
AC Models
• Inputs: 220 /110 Volts AC
• Outputs: 24 Volts AC.
DC Models
• Inputs: 12 Volts DC. (12 Volts 9 Amp*Hr
battery). Optional connection to solar panel.
• Outputs: DC latching.
MiniGal-Star
A non modular controller 16 Outputs, 8 Inputs in
a
"Small Casing".
Gal-Star and Gal-Star EX
Gal-Star is a modular controller. Its casing
contains slots in which I/O cards can be
inserted.
Casing
There are two types of casing:
Small Casing: 5 Slots.
Large Casing: 7 Slots. The large casing has a
future preparation for: Integral L-485, Integral
Radio Adapter, Integral ECpH Adapter.
Maximum
Outputs/Inputs
The Gal-Star is designed to have a maximum of 32
outputs and 24 inputs. The inputs can be a
combination of discrete inputs and analogs. The
maximum configuration can only be achieved with
the EX (large casing) model.
I/O Cards
• 8 * 24 VAC Output Card
• 8 * DC Latching Output Card
• 8 * Discrete (On/Off) Input Card
• 8 * Analog (4-20mA or 0-2V) Card
Capacity
• 2 irrigation heads
• 3 fertilizer pumps per head
• 4 water meters per head
• 4 filters per head
• Up to 32 valves per head
• 64 irrigation programs per head
• 10 fertilizing programs per head
Programming Features
• Irrigation duration according to Time, Volume
or
Automatic calculation of Volume per area.
• Fertilization according to Time, Volume,
Proportional, and according to ECpH.
• Sequential operation
• Priority operation
• Scheduled operation according to:
• Cycle (1 Min. to 360 Days).
• Daily (Monday - Sunday).
• Conditioned Operation: According to Input or
Logic Condition.
• Alarm Settings: including: Overflow and Under
flow, Water Pulse Fault, Uncontrolled Water,
Pause Device and more.
• Flow Rate Limit: Automatic mechanism of
program ordering to prevent exceeding of a flow
rate limit.
• Flow Rate Division: The ability to divide the
flow rate and accumulation between valves which
are
simultaneously irrigating with the same water
meter or the same fertilizer program. The
division is made according to the nominal flow
rates set for the valves.
Accumulations
Accumulation of Water, Time and Fertilizers
independently for each valve even when working
with the same water meter.
PC Connections
The controller has an RS232 port to connect to a
PC. The PC connection may be used for:
• Remote Control Operation.
• Data acquisition.
• Graphical presentation.
• Controller Network Operation.
• Cellular (GPRS) connection. |